Safe is safe:
Quality check
for pumps.

Better safe than sorry: quality check for pumps.

Home 9 Services & Benefits 9 Test fields for pumps
In our modern test facilities, we put the entire range of reconditioned pumps through their paces before delivery. In addition, we offer comprehensive special tests - according to your requirements and specifications. For permanently reliable function and the best possible safety.

Our services at a glance:

  • 3 flexible and very variable designed test bays for pumps
  • Testing of dry-installed pumps as well as submersible pumps
  • Special equipment for testing canned motor pumps (e.g. from the manufacturer Hermetic)

An overview of our available voltage sources:

1. test sections for submersible pumps

Nominal diameter
Nominal pressure
Flow rate [m³/h]
Pressure [bar]
DN65
PN10
0 - 60 m³/h
Max. 10 bar
DN65
PN16
0 - 50 m³/h
Max. 16 bar
DN100
PN16
0 - 280 m³/h
Max. 16 bar
DN300
PN16
0 - 2,520 m³/h
Max. 10 bar

2. test sections for dry pumps installed

Nominal diameter
Nominal pressure
Flow rate [m³/h]
Pressure [bar]
DN65
PN10
0 - 45 m³/h
Max. 10 bar
DN100
PN16
0 - 280 m³/h
Max. 16 bar
DN300
PN10
0 - 600 m³/h
Max. 16 bar

3. test sections for dry pumps set up

Nominal diameter
Nominal pressure
Flow rate [m³/h]
Pressure [bar]
DN150
PN16
0 - 360 m³/h
With an optional pressure absorption of 16 or 24 bar

Important questions about pump testing

When is a pump test on a test bench advisable?

A test bench measurement is useful when the hydraulic performance needs to be verified after a repair or when deviations from expected operation need to be investigated. It goes beyond a simple functional or leak test. Under defined conditions, relevant operating values ​​can be recorded and compared with target values ​​or a reference characteristic curve. The specific benefit depends on the agreed test objective.

What information can be provided by a measured pump characteristic curve?

A measured characteristic curve shows how the delivery head and flow rate behave across different operating points. Together with performance data, it allows for an assessment of whether the pump achieves the agreed-upon hydraulic performance and whether any anomalies exist. The results can serve as a basis for acceptance testing or comparison. Therefore, the scope of measurement, tolerances, and documentation should be agreed upon before testing.

How do we check whether a pump can be tested on an existing test bench?

We compare the pump design, connection size, expected flow rate, pressure, and electrical connection data with the available test bench. Additionally, the medium, installation, direction of rotation, controllability, and desired measuring points are relevant. If a requirement falls outside the standard ranges, we examine possible adaptations or an alternative test concept. Therefore, the technical data should be fully coordinated before delivery.

How are acceptance criteria for a pump test determined?

Before testing, we agree on measured values, operating points, tolerances, reference curve, and the scope of documentation. Depending on the project, conveying height, conveying volume, power consumption, and other values ​​may be relevant. Clear criteria enable a transparent evaluation instead of subsequent interpretation of individual measurement points.

Why is a pump characteristic curve recorded over several operating points?

A single operating point only shows a portion of the hydraulic behavior. Multiple measurement points reveal whether the curve and power consumption are plausible across the relevant operating range. This makes it easier to distinguish deviations from measurement errors or an unsuitable setting.